18
GB
Table of burner and nozzle specifications
Table 1 Liquid gas Natural gas
Thermal power
kW (p.c.s.*)
Capacity*
g/h
Burner Diameter
(mm)
Nominal Reduced
Bypass
1/100
(mm)
Nozzle
1/100
(mm)
*** **
Nozzle
1/100
(mm)
Capacity*
l/h
Rapid (Large)
(R)
100 3.00 0.70 41 86 218 214 116 286
Semi-rapid
(Medium) (S)
75 1.90 0.40 30 70 138 136 106 181
Auxiliary
(Small) (A)
55 1.00 0.40 30 50 73 71 79 95
Supply
pressure
Nominal (mbar)
Minimal (mbar)
Maximised (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50.37 MJ/kg
*** Butane P.C.S. = 49.47 MJ/kg
Natural P.C.S. = 37.78 MJ/m³
S
R
A
ø 180
CX 61 N1 CKD
TECHNICAL DATA
Oven dimensio ns
(HxWxD)
32x43.5x40 cm
Volume
56 l
Useful
measurements
relating to the oven
compartment
width 42 cm
depth 44 cm
height 8.5 cm
Burners
may be adapted for use with any
type of gas shown on the data plate
Voltage and
frequency
see data plate
ENERGY LABEL
Directive 2002/40/EC on the label
of electric ovens.
Regulation EN 50304
Declared energy consumption for
Natural convection Class
heating mode
:
Static
EC Directives: 73/23/EEC dated
19/02/73 (Low Voltage) and
subsequent amendments -
89/336/EEC dated 03/05/89
(Electromagnetic Compatibility)
and subsequent amendments -
90/369/EEC dated 29/06/90 (Gas)
and subsequent amendments -
93/68/EEC
dated 22/07/93 and
subsequent amendments -
2002/96/EC.