Table of burner and nozzle specifications
Table 1 Liquid Gas Natural Gas
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nozzle
1/100
Flow*
l/h
Burner
Nominal Reduced (mm) (mm) *** ** (mm) (mm)
Fast
(Large)(R)
100 3.00 0.7 41 86 218 214 116 286 143 286
Semi Fast
(Medium)(S)
75 1.90 0.4 30 70 138 136 106 181 118 181
Auxiliary
(Small)(A)
55 1.00 0.4 30 50 73 71 79 95 80 95
Triple Ring
(TC)
130 3.25 1.5 63 236 232 309 309
Oven - 2.60 1.0 52 78 189 186 119 248 132 248
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
13
6,5
18
* At 15°C 1013 mbar-dry gas *** Butane P.C.S. = 49,47 MJ/Kg
**
Propane
P.C.S. = 50,37 MJ/Kg Natural P.C.S. = 37,78 MJ/m³
TECHNICAL DATA
Oven Dimensions
HxWxD
31x41x41 cm
Volume
Useful
measurements
relating to the
oven compartment
width 46 cm
de
p
th 42 cm
hei
g
ht 8,5 cm
Voltage and
frequency
see data
p
late
Burners
ma
y
be ada
p
ted for use with an
y
t
yp
e of
g
as shown on the data
p
late.
EC Directives 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
04/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09 (Gas)
1275/2008(Stand-by/Off-mode)
CJ 65S G17 RU /HA
58l
3. Having adjusted the flame to the required low
setting, while the burner is alight, quickly change
the position of the knob from minimum to
maximum and vice versa several times, checking
that the flame does not go out.
4. Some appliances have a safety device
(thermocouple) fitted. If the device fails to work
when the burners are set to the low flame setting,
increase this low flame setting using the adjusting
screw.
5. Once the adjustment has been made, replace the
seals on the by-passes using sealing wax
! If the appliance is connected to liquid gas, the
regulation screw must be fastened as tightly as
possible.
! Once this procedure is finished, replace the old
rating sticker with one indicating the new type of gas
used. Stickers are available from any of our Service
Centres.
! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet pipe (in
order to comply with current national regulations).
S
R
TC A
2x65
2x99
2x107
1. Turn the tap to the low flame position.
2. Remove the knob and adjust the adjustment
screw, which is positioned in or next to the tap pin,
until the flame is small but steady.
Adjusting the burners’ primary air :
Does not require adjusting.
Setting the burners to minimum: